Parametric specs for Display-Oriented ADCs
Resolution (±Counts) 2000
# Input Channels 1
Conv. Rate (ksps) (max) 0.03
Data Bus 7-Segment
Diff/S.E. Input Diff. Only
Internal VREF (V) (nominal) 2.8
External VREF (V) (max) 9
Bipolar VIN (±V) (max) 3.5
Package/Pins PDIP/40
Budgetary
Price (See Notes)
9.5
非表示にする

簡易ブロック図

Technical Docs

データシート 低電力、3 1/2桁ADC Aug 01, 1984
チュートリアル Delta-Sigma ADCs Replace Integrating ADCs for Panel Meters
チュートリアル Understanding Integrating ADCs

サポートとトレーニング

技術質問への回答についてはナレッジベースで検索ください。

絞り込まれた検索

マキシムでは、お客様の技術的質問にお答えするため、アプリケーションエンジニアの専任チームも配置しています。 サポートセンター をご利用ください。

パラメーター

Parametric specs for Display-Oriented ADCs
Resolution (±Counts) 2000
# Input Channels 1
Conv. Rate (ksps) (max) 0.03
Data Bus 7-Segment
Diff/S.E. Input Diff. Only
Internal VREF (V) (nominal) 2.8
External VREF (V) (max) 9
Bipolar VIN (±V) (max) 3.5
Package/Pins PDIP/40
Budgetary
Price (See Notes)
9.5

主な特長

  • Improved 2nd Source!
  • Power dissipation guaranteed less than 1mW-9V battery life 3000 hours typical
  • Guaranteed first reading recovery from overrange
  • Zero Input Gives Zero Reading
  • Drives LCD Displays Directly
  • Low Noise (15μV p-p) without hysteresis or overrange hangover
  • True Differential Reference and Input
  • Monolithic, Low Power CMOS

アプリケーション/用途

  • コンダクタンス
  • 電流
  • 材料厚
  • 圧力
  • 抵抗
  • 速度
  • 温度
  • 電圧

説明

The Maxim ICL7126 is a monolithic analog to digital converter with very high input impedance. On-board active components include segment drivers, segment decoders, voltage reference and a clock circuit. The ICL7126 directly drives a non-multiplexed liquid crystal (LCD) display, requiring no external display drive circuitry. Significantly reduced power consumption makes the ICL7126 a superior device, especially for portable systems.

Versatility and accuracy are inherent features of this converter. The dual-slope conversion technique automatically rejects interference signals common in industrial environments. The true differential input and reference are particularly useful when making ratiometric measurements (ohms or bridge transducers), and the zero-integrator phase in Maxim's ICL7126 eliminates overrange hangover and hysteresis effects. The Zero Integrator phase also allows the use of larger auto zero capacitors reducing noise further. Finally, this device offers high accuracy by lowering rollover error to less than one count and zero reading drift to less than 1μV/°C.

簡易ブロック図

ICL7126:標準動作回路 ICL7126:標準動作回路 Zoom icon

Technical Docs

データシート 低電力、3 1/2桁ADC Aug 01, 1984
チュートリアル Delta-Sigma ADCs Replace Integrating ADCs for Panel Meters
チュートリアル Understanding Integrating ADCs

サポートとトレーニング

技術質問への回答についてはナレッジベースで検索ください。

絞り込まれた検索

マキシムでは、お客様の技術的質問にお答えするため、アプリケーションエンジニアの専任チームも配置しています。 サポートセンター をご利用ください。