Description

The MAX6646/MAX6647/MAX6649 are precise, two-channel digital temperature sensors. The devices accurately measure the temperature of their own die and a remote PN junction, and report the temperature in digital form using a 2-wire serial interface. The remote PN junction is typically the emitter-base junction of a common-collector PNP on a CPU, FPGA, or ASIC.

The 2-wire serial interface accepts standard system management bus (SMBus) write byte, read byte, send byte, and receive byte commands to read the temperature data and to program the alarm thresholds. To enhance system reliability, the MAX6646/MAX6647/MAX6649 include an SMBus timeout. A fault queue prevents the active-low ALERT and active-low OVERT outputs from setting until a fault has been detected one, two, or three consecutive times (programmable).

The MAX6646/MAX6647/MAX6649 provide two system alarms: active-low ALERT and active-low OVERT. Active-low ALERT asserts when any of four temperature conditions are violated: local overtemperature, remote overtemperature, local undertemperature, or remote undertemperature. Active-low OVERT asserts when the temperature rises above the value in either of the two active-low OVERT limit registers. The active-low OVERT output can be used to activate a cooling fan, or to trigger a system shutdown.

Measurements can be done autonomously, at the programmed conversion rate, or in a single-shot mode. The adjustable conversion rate allows optimizing supply current and temperature update rate to match system needs.

Remote accuracy is ±1°C maximum error between +60°C and +145°C with no calibration needed. The MAX6646/MAX6647/MAX6649 operate from -55°C to +125°C, and measure temperatures between 0°C and +145°C. The MAX6646/MAX6647/MAX6649 are available in an 8-pin µMAX® package.
MAX6646, MAX6647, MAX6649: Typical Operating Circuit MAX6646, MAX6647, MAX6649: Typical Operating Circuit Enlarge+

Key Features

  • Dual Channel: Measures Remote and Local Temperature
  • 0.125°C Resolution
  • High Accuracy ±1°C (max) from +60°C to +145°C (Remote), and ±2°C (max) from +60°C to +100°C (Local)
  • Measures High-Ideality Thermal Diodes Up to
    • +170°C (Apparent)
    • +145°C (Real)
  • Two Alarm Outputs: Active-Low ALERT and Active-Low OVERT
  • Programmable Under/Overtemperature Alarm Temperature Thresholds
  • Programmable Conversion Rate
  • SMBus-Compatible Interface
  • SMBus Timeout

Applications/Uses

  • Desktop Computers
  • Graphics Processors
  • Multichip Modules
  • Notebook Computers
  • Servers
  • Test and Measurement Equipment
  • Thin Clients
  • Workstations
Part NumberSensor TypeAlarm OutputFunctionsInterfaceChannelsAccuracy
(±°C)
Parasite Pwr.Temp. Thresh.Temp. Resolution
(bits)
Oper. Temp.
(°C)
Package/PinsBudgetary
Price
See Notes
MAX6646 Remote
Alert
Overt
Dual Temperature Alarms
Remote & Local Sensor
2-Wire/I2C/SMBusOne1NoProgrammable11-55 to +125
UMAX/8
$1.91 @1k
MAX6647 0.8
UMAX/8
$1.67 @1k
MAX6649 0.8
UMAX/8
$2.08 @1k
See All Temperature Sensors (111)
Pricing Notes:
This pricing is BUDGETARY, for comparing similar parts. Prices are in U.S. dollars and subject to change. Quantity pricing may vary substantially and international prices may differ due to local duties, taxes, fees, and exchange rates. For volume-specific and version-specific prices and delivery, please see the price and availability page or contact an authorized distributor.

CAD Symbols and Footprints

  • MAX6649MUA+
  • MAX6649MUA+T
  • MAX6649YMUA+
  • Device   Fab Process   Technology   Sample size   Rejects   FIT at 25°C   FIT at 55°C  

    Note : The failure rates are summarized by technology and mapped to the associated material part numbers. The failure rates are highly dependent on the number of units tested.

    Quality Management System >
    Environmental Management System >

     
    Status:
    Package:
    Temperature:

    Related Resources


    MAX30131
    1-, 2-, 4-Channel, Ultra-Low Power Electrochemical Sensor AFEs

    • Multichannel Operation
    • High Accuracy and Precision
    • Autonomous Modes with 256 Word Configurable FIFO and Programmable Alarm

    MAX30132
    1-, 2-, 4-Channel, Ultra-Low Power Electrochemical Sensor AFEs

    • Multichannel Operation
    • High Accuracy and Precision
    • Autonomous Modes with 256 Word Configurable FIFO and Programmable Alarm

    MAX30134
    1-, 2-, 4-Channel, Ultra-Low Power Electrochemical Sensor AFEs

    • Multichannel Operation
    • High Accuracy and Precision
    • Autonomous Modes with 256 Word Configurable FIFO and Programmable Alarm

    MAXM86161
    Single-Supply Integrated Optical Module for HR and SpO2 Measurement

    • Complete Single-Channel Optical Data Acquisition System
    • Built-In Algorithm Further Enhances Rejection of Fast Ambient Transients
    • Optimized Architecture for Reflective Heart Rate and SpO2 Monitoring

    MAX30208
    ±0.1°C Accurate, I2C Digital Temperature Sensor

    • High Accuracy and Precision
    • Low Power Consumption
    • Small Size


    Belle Isle 2020
    05/29/2020 - 05/31/2020, Detroit, MI
    2020 Detroit Grand Prix - Chevrolet Detroit Grand Prix presented by Lear Fast Facts The Chevrolet Detroit Grand Prix presented by Lear was hosted on Belle Isle, May 29 - 30 2020. The event featured the cars of the NTT IndyCar Series, the IMSA WeatherTech SportsCar Championship and the Trans Am Series presented by Pirelli. The weekend is collectively referred to as the Chevrolet Detroit Grand Prix presented by Lear and it once again featured the Chevrolet Dual in Detroit IndyCar doubleheader.

    RSVP