Product Details
The MAX6505/MAX6506 have an ALARM output that asserts when the temperature is above the factory-programmed thresholds (available from -40°C to +125°C). They also have a WARN output that asserts when the temperature is several degrees below the ALARM threshold. The difference between the ALARM and WARN thresholds (ΔTAW) is pin selectable to +5°C, +10°C, +20°C, or +30°C. The MAX6505's logic outputs are open drain, while the MAX6506's logic outputs are push-pull.
The MAX6507 has open-drain outputs (active-low OVER, OK), and the MAX6508 has push-pull outputs (OVER, active-low OK), each with two factory-programmed threshold temperatures (TOVER and TUNDER) in the wide range of -40°C to +125°C. The overtemperature output asserts when the temperature is above TOVER. When the temperature is in the desired window (less than TOVER and greater than TUNDER), OK (active-low OK) asserts.
The MAX6505–MAX6508 are accurate to ±0.5°C (typ), ±5.5°C (max). Operating from a +2.5V to +5.5V supply, these low-cost devices typically consume 30µA supply current and require no external components for setting trip points. The MAX6505–MAX6508 are available in a 6-pin SOT23 package.
Key Features
- ±0.5°C (typ) Threshold Accuracy Over Full Temperature Range
- No External Components Required
- Low Cost
- 30µA (typ) Supply Current
- Factory-Programmed Thresholds from -40°C to +125°C in 5°C Increments
- Open-Drain Outputs (MAX6505/MAX6507), Push-Pull Outputs (MAX6506/MAX6508)
- Pin Selectable 2°C, 10°C Hysteresis (MAX6507/MAX6508)
- Pin Selectable +5°C, +10°C, +20°C, +30°C TALARM - TWARN (MAX6505/MAX6506)
- SOT23 Package
Applications/Uses
- Fan Control
- Temperature Alarms
- Temperature Control
Switch Type | Local |
Interface | Logic |
Functions | Temperature Switch/Temperature Comparator |
Accuracy (±°C) | 0.5 |
Temp. Thresh. (°C) | Factory Programmed |
Package/Pins | SOT23/6 |
Budgetary Price (See Notes) | $0.90 @1k |
Technical Docs
Data Sheet | Dual Trip SOT Temperature Switches | Mar 22, 2011 | |
Tutorial | Thermal Management Handbook |
Click any title below to view the detail page where available.
Support & Training
Search our knowledge base for answers to your technical questions.
Filtered SearchOur dedicated team of Applications Engineers are also available to answer your technical questions. Visit our support portal
Parameters
Switch Type | Local |
Interface | Logic |
Functions | Temperature Switch/Temperature Comparator |
Accuracy (±°C) | 0.5 |
Temp. Thresh. (°C) | Factory Programmed |
Package/Pins | SOT23/6 |
Budgetary Price (See Notes) | $0.90 @1k |
Key Features
- ±0.5°C (typ) Threshold Accuracy Over Full Temperature Range
- No External Components Required
- Low Cost
- 30µA (typ) Supply Current
- Factory-Programmed Thresholds from -40°C to +125°C in 5°C Increments
- Open-Drain Outputs (MAX6505/MAX6507), Push-Pull Outputs (MAX6506/MAX6508)
- Pin Selectable 2°C, 10°C Hysteresis (MAX6507/MAX6508)
- Pin Selectable +5°C, +10°C, +20°C, +30°C TALARM - TWARN (MAX6505/MAX6506)
- SOT23 Package
Applications/Uses
- Fan Control
- Temperature Alarms
- Temperature Control
Description
The MAX6505/MAX6506 have an ALARM output that asserts when the temperature is above the factory-programmed thresholds (available from -40°C to +125°C). They also have a WARN output that asserts when the temperature is several degrees below the ALARM threshold. The difference between the ALARM and WARN thresholds (ΔTAW) is pin selectable to +5°C, +10°C, +20°C, or +30°C. The MAX6505's logic outputs are open drain, while the MAX6506's logic outputs are push-pull.
The MAX6507 has open-drain outputs (active-low OVER, OK), and the MAX6508 has push-pull outputs (OVER, active-low OK), each with two factory-programmed threshold temperatures (TOVER and TUNDER) in the wide range of -40°C to +125°C. The overtemperature output asserts when the temperature is above TOVER. When the temperature is in the desired window (less than TOVER and greater than TUNDER), OK (active-low OK) asserts.
The MAX6505–MAX6508 are accurate to ±0.5°C (typ), ±5.5°C (max). Operating from a +2.5V to +5.5V supply, these low-cost devices typically consume 30µA supply current and require no external components for setting trip points. The MAX6505–MAX6508 are available in a 6-pin SOT23 package.
Technical Docs
Data Sheet | Dual Trip SOT Temperature Switches | Mar 22, 2011 | |
Tutorial | Thermal Management Handbook |
Support & Training
Search our knowledge base for answers to your technical questions.
Filtered SearchOur dedicated team of Applications Engineers are also available to answer your technical questions. Visit our support portal