Key Features
- Operate from 2.8V to 14V
- ±2.5% Current-Monitoring Accuracy
- 1% Accurate 10-Bit ADC Monitors 12/8 Voltage Inputs
- Single-Ended or Differential ADC for System Voltage/Current Monitoring
- Integrated High-Side Current-Sense Amplifier
- 12/8 Monitored Inputs with Overvoltage/Undervoltage/Early Warning Limit
- Nonvolatile Fault Event Logger
- Power-Up and Power-Down Sequencing Capability
- Independent Secondary Sequence Block
- 12/8 Outputs for Sequencing/Power-Good Indicators
- Two Programmable Fault Outputs and One Reset Output
- Eight General-Purpose Inputs/Outputs Configurable as:
- Dedicated Fault Outputs
- Watchdog Timer Function
- Manual Reset
- Margin Enable
- SMBus (with Timeout) or JTAG Interface
- Flash Configurable Time Delays and Thresholds
- -40°C to +85°C Operating Temperature Range
Applications/Uses
- Networking Equipment
- Servers
- Storage/RAID Systems
- Telecom Equipment (Base Stations, Access)
Description
The internal 1% accurate 10-bit ADC measures each input and compares the result to one overvoltage, one undervoltage, and one early warning limit that can be configured as either undervoltage or overvoltage. A fault signal asserts when a monitored voltage falls outside the set limits. Up to three independent fault output signals are configurable to assert under various fault conditions.
Because the MAX16065/MAX16066 support a power-supply voltage of up to 14V, they can be powered directly from the 12V intermediate bus in many systems.
The integrated sequencer provides precise control over the power-up and power-down order of up to twelve (MAX16065) or up to eight (MAX16066) power supplies. Eight outputs (EN_OUT1–EN_OUT8) are configurable with charge-pump outputs to directly drive external n-channel MOSFETs.
The MAX16065/MAX16066 include eight/six programmable general-purpose inputs/outputs (GPIO_s). GPIO_s are flash configurable as dedicated fault outputs, as a watchdog input or output, or as a manual reset.
The MAX16065/MAX16066 feature nonvolatile fault memory for recording information during system shutdown events. The fault logger records a failure in the internal flash and sets a lock bit protecting the stored fault data from accidental erasure. An SMBus or a JTAG serial interface configures the MAX16065/MAX16066. The MAX16065 is available in a 48-pin, 7mm x 7mm, TQFN package, and the MAX16066 is available in a 40-pin, 6mm x 6mm, TQFN package. Both devices are fully specified from -40°C to +85°C.