APPLICATION NOTE 4904

78M6613 Safety Precautions

By: Ken Harada

Abstract: This application note discusses the Teridian 78M3301, a single-phase power-measurement IC. Safety precautions for test equipment, evaluation (EV) boards, in-circuit emulators, and communications interfaces are described. The article explains that when a shunt is used as a current sensor with the 78M6613, then V3P3 must be directly connected to the NEUTRAL wiring for precise energy-measurement accuracy. This topology presents two potential safety issues: the 78M6613 ground pin is normally -3.3V below earth ground; and in the event of a LINE wiring reversal, the 78M6613 ground pin becomes 120/240 VAC. The article thus explains that any external test equipment attached to the 78M6613 is subject to this -3.3V ground reference disparity.


Related Parts
78M6613 Free Sample
Next Steps
EE-Mail Subscribe to EE-Mail and receive automatic notice of new documents in your areas of interest.
Download Download, PDF Format
© , Maxim Integrated Products, Inc.
The content on this webpage is protected by copyright laws of the United States and of foreign countries. For requests to copy this content, contact us.
APP 4904:
APPLICATION NOTE 4904,AN4904, AN 4904, APP4904, Appnote4904, Appnote 4904